Chapter 5
EMI And Environmental Type Tests
RuggedBackbone™ RX5000
Installation Guide
32
Test Description Test Levels
Severity
Levels
A.C. Power ports
2.5kV common, 1kV
diff. mode@1MHz
3
Signal ports 30V Continuous, 300V for 1s 4
IEC 61000-4-16 Mains Frequency Voltage
D.C. Power ports 30V Continuous, 300V for 1s 4
IEC 61000-4-17
Ripple on D.C.
Power Supply
D.C. Power ports 10% 3
Signal ports 2kVAC (Fail-Safe Relay output) N/A
D.C. Power ports 1.5kVDC N/AIEC 60255-5 Dielectric Strength
A.C. Power ports 2kVAC N/A
Signal ports 5kV (Fail-Safe Relay output) N/A
D.C. Power ports 5kV N/AIEC 60255-5 H.V. Impulse
A.C. Power ports 5kV N/A
a
RuggedCom-specified severity levels
Table 16: IEEE 1613 (C37.90.x) EMI Immunity Type Tests
b
Test Description Test Levels
Enclosure Contact +/-2kV, +/-4kV, +/- 8kV
IEEE C37.90.3 ESD
Enclosure Air +/-4kV, +/-8kV, +/-15kV
IEEE C37.90.2 Radiated RFI Enclosure ports 35 V/m
Signal ports +/- 4kV @ 2.5kHz
D.C. Power ports +/- 4kV
A.C. Power ports +/- 4kV
IEEE C37.90.1 Fast Transient
Earth ground ports +/- 4kV
Signal ports 2.5kV common mode @1MHz
D.C. Power ports 2.5kV common, 1kV diff. mode@1MHzIEEE C37.90.1 Oscillatory
A.C. Power ports 2.5kV common, 1kV diff. mode@1MHz
Signal ports 5kV (Fail-Safe Relay output)
D.C. Power ports 5kVIEEE C37.90 H.V. Impulse
A.C. Power ports 5kV
Signal ports 2kVAC
D.C. Power ports 2kVDCIEEE C37.90 Dielectric Strength
A.C. Power ports 2kVAC
b
Meets Class 2 requirements for an all fiber configuration. Class 1 for copper ports.
Table 17: Environmental Type Tests
Test Description Test Levels
IEC 60068-2-1 Cold Temperature Test Ad -40°C, 16 Hours