Seitenansicht 24
RuggedBackbone™ RX5000
Installation Guide
Chapter 3
Installation
DC Power Supply Wiring 19
Each RX5000 Power Module is equipped with a Phillips screw terminal block (Figure 20) for main power
connection. The Phillips Screw Terminal Block has Phillips screws with compression plates, allowing either bare
wire connections or crimped terminal lugs. We recommend the use of #6 size ring lugs to ensure secure, reliable
connections under severe shock or vibration. The terminal block has a safety cover which must be removed
via two Phillips screws before connecting any wires. The safety cover must be reattached after wiring to ensure
personnel safety.
CAUTION!
A permanently connected RuggedBackbone™ RX5000 must have a readily accessible disconnect
device incorporated external to the equipment.
WARNING!
The RX5000 may have two (2) power supplies installed and be supplied from multiple power sources.
Service personnel must isolate both power supplies prior to servicing.
Figure 20: RX5000 Power Connector