2. Installation
RuggedCom® RuggedSwitch® 12 M2100 Installation Guide Rev 1.0
2.2. Power Supply Wiring and Grounding
Figure 2.2. M2000 Series Phillips Screw Terminal Block
The M2000 Family supports dual redundant power supplies - "Power Supply 1 (PS1)" and "Power
Supply 2 (PS2)". The connections for PS1, PS2 and the fail-safe relay are located on the terminal block
as shown in Figure 2.2, “M2000 Series Phillips Screw Terminal Block”.
The M2000 Family chassis ground connection, shown in Figure 2.3, “Chassis Ground Connection”,
uses a #6-32 screw. It is recommended to terminate the ground connection in a #6 ring lug, and to use
a torque setting not exceeding 1.7 Nm (15 in.lbs).
Figure 2.3. Chassis Ground Connection
The M2000 Family is equipped with a Phillips Screw Terminal Block. The Phillips Screw Terminal Block
has Phillips screws with a compression plate allowing either bare wire connections or crimped terminal
lugs. RuggedCom recommend the use of #6 size ring lugs to ensure secure, reliable connections
under severe shock or vibration. The terminal block has a safety cover which must be removed via
two Phillips screws before connecting any wires. The safety cover must be re-attached after wiring to
ensure personnel safety. Refer to Table 3 below for a description of each terminal as well as sections
5.2.1 through 5.2.3 for wiring examples.
Terminal # Description Usage
1 PS1 Live / +
PS1 Live / + is connected to the positive (+) terminal if the power source is
DC or to the (Live) terminal if the power source is AC.
2 PS1 Surge Ground
PS1 Surge Ground is connected to the Chassis Ground via a jumper on
the terminal block. Surge Ground is used as the ground conductor for all
surge and transient suppression circuitry. NOTE: Surge Ground must be
disconnected from Chassis Ground during HIPOT (dielectric strength)
testing.